“We do not want the house torn apart” is the brief on most cabling enquiries. Good. Neither do we. A Cat6 install that looks like a renovation is a failed route plan, not a thorough one.
This is how we actually get cable through Berkshire houses. Pair it with how many points and Cat6 vs Cat5e.
The loft is the motorway
On a standard two-storey house the AP cables live in the loft and drop into ceilings or down a built-in. TV and office plates often come down a corner, a wardrobe, or a service void next to a soil stack.
What we need from you: a usable hatch, some boards to kneel on, and honesty about insulation depth. What we do not need: permission to open every room’s plaster.
New-build lofts in Bracknell and parts of Reading are often easy. Older eaves in Windsor and Eton are tighter. Both still beat chasing a hallway.
A boarded loft with a clear run to the eaves is the best day we have. We pull, we drop, we terminate, and the bedrooms never look like a site. Deep, unboarded insulation is slower, not impossible. We board what we kneel on. We do not wade through it and hope the cable sits where we left it.
Drops from the loft are how access points get into a landing ceiling without a chase. The same loft feed can come down a built-in wardrobe to an office plate, or down a corner boxing to a TV wall. That is not luck. That is looking at the house the way a first-fix electrician does, not the way a floor plan does.
Other routes that are not demolition
- Under-stairs and cupboard drops to the incoming broadband
- External trunking along a side elevation, colour matched, into a rear office
- Garage voids for CCTV and a workshop AP
- Existing alarm or TV ducts, if they are actually free and not full of ancient coax
- Suspended floors in selected rooms, lifting a few boards, not the entire floor
Garden offices almost always combine a short external run with an internal AP. See garden office without dropouts.
The under-stairs cupboard is where most Berkshire broadband already lives. Getting Cat6 out of that cupboard and into the loft is often one neat rise in a corner, not a hallway demolition. If the cupboard is packed with coats and a boiler, we will say so on survey. Space for a small switch is part of the route, not an afterthought.
External trunking has a bad reputation from ugly white plastic on a front elevation. Done on a side wall, clipped properly, painted in, it is how we reach a rear study or a garden door without opening plaster. We would rather you see a tidy run than pretend a cavity we cannot test is “hidden”.
Garage voids are useful on detached and semi plots in Maidenhead and Bracknell. A camera on the gable and an AP for a workshop can share that space. Damp floors and a “leave it in the coil” attitude are not part of that plan.
Suspended floors in older Windsor and Maidenhead houses let us lift a few boards, run, and relay. That is slower and dearer than a loft drop. It is still not ripping the house up. We lift what we need. We do not lift a whole reception “to be sure”.
When we do chase, and why we try not to
Chasing a wall is for a plate that has no other honest path, on a wall you were already decorating. It is dusty, it is slow, and it is how quotes jump.
We will chase if you insist on a hidden plate on a solid internal wall with no void. We will explain the mess first. Surface trunking along a skirting, done neatly, is not a moral failure. It is reversible, testable, and kinder to period plaster.
Solid floors downstairs in some 1960s and 1970s houses block under-floor dreams. Then we go around, not through the slab.
A chase through lath and plaster in a period house is how you pay twice: once for the cable, once for the plasterer. We will not sell that as the default. If you are already stripping that wall, tell us. Then a hidden plate is honest.
We would rather run painted mini-trunking along a skirting in a utility, or come down a built-in, than chase a feature wall in the lounge. Hidden is not always better. Hidden and untestable is worse.
If the only remaining option is a chase, we agree the line, the making-good, and whether you are decorating after us. We do not “just pop a groove in” and leave you with a dusty stripe you did not expect.
What “tidy” looks like at handover
Labelled wall plates. A small patch panel or at least a labelled bundle at the switch. No spare coils stuffed in insulation. No outdoor cable used as a cheap indoor run. Test results if you want them.
A cable you cannot test is not a professional install. Stapling Cat6 to the outside of a fascia “because it is hidden from the road” is how UV and wind finish the job for you.
Indoor cable indoors. Outdoor sheath outside, in containment, not draped over a gutter. Mixing those to save a tenner is how the run fails after one summer.
Plates sit where furniture will actually go, square, at a height you can patch without moving a sideboard every time. A plate in the middle of a chimney breast “because the drawing was centred” is not tidy. It is a fight with the TV.
At the cupboard we leave something you can understand: which lead is the office, which is the landing AP, which is the garden. UniFi switching in that cupboard is a common finish so you can see the ports afterwards. The copper still has to be labelled first.
Houses that need more conversation
- Listed or conservation: period property WiFi
- Long plots: Virginia Water and Ascot often need a mix of loft and external
- Flats: West London WiFi routes are communal and slower
We plan this on survey in Windsor, Maidenhead, Ascot, Virginia Water and Sunningdale.
If your fear is dust, send loft photos. Most of the time the answer is “we can stay in the roof”.
Listed and conservation houses are a route problem, not a reason to give up on Ethernet. Existing voids, surface containment, and reversible work are the toolkit. We will not hack a cornice to hide a Cat6. We will show you a painted run and a loft drop and let you choose.
Long plots are two or three methods on one job. Loft for the house APs. External for the garden office or the gate. Maybe a garage as a midpoint so a single heroic pull does not become a voltage-drop argument. That is still not demolition. It is a plan.
Flats and houses with no loft need honesty about communal areas, neighbours, and what we are allowed to open. Slower. Still usually possible without chasing every room.
Solid-wall 1960s houses with no eaves void are the ones where we talk about trunking like adults on the first call, not after we have made a mess.
What a survey photo should show us
A wide shot of the loft hatch, a shot into the loft, the cupboard where the broadband lives, and the wall where you want a plate. With those four pictures we can usually say whether this is a loft-drop job, an external trunking job, or the rare chase.
If the loft is boarded and the hatch is not glued shut under three coats of paint, we are optimistic. If the only void is a 1930s eaves full of old tanks, we will talk about painted trunking like adults. Period property WiFi is the extreme of that conversation.
Do not wait until decoration week and then ask for hidden cable tomorrow. Hidden is a planning problem. Tidy surface is a day.
If you are mid-renovation, send the first-fix photos too. That is when hidden cable is cheap. Asking for hidden cable the week the decorator books in is how everyone is unhappy.
Working around other trades
We would rather go in after the electrician has finished a first fix and before the plasterer closes everything, if you are already renovating. On a lived-in house we protect carpets, use the hatch, and we do not treat your kitchen as a workshop.
Garden runs want a dry day and a route that will not be eaten by a future patio. Mark where you think a path might go. We have pulled cable beautifully, then watched a landscaper find it.
Testing at the end is not optional. A plate that “has a link light” can still be a bad termination. We test, label, and leave you with a switch that makes sense. That is the whole point of data cabling as a service rather than a drum of cable from a shed.
If the decorator, the kitchen fitter, or the AV person also needs the same void, tell us. Two trades in one boxing on different days is how someone staples through a Cat6. One conversation on the survey saves that.
Powerline is not the fallback when a route looks awkward. Awkward routes are what the survey is for. If we can loft it, we loft it. If we cannot, we say so, and we show you the external or surface option rather than selling you a compromise that fails on a UK ring main.